<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Homogenisation &#8211; Thermaflo</title>
	<atom:link href="https://www.thermaflo.co.nz/product-category/processing/equipment/homogenisation/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.thermaflo.co.nz</link>
	<description>Liquid Food Process Systems</description>
	<lastBuildDate>Tue, 30 Aug 2022 23:36:45 +0000</lastBuildDate>
	<language>en-NZ</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.thermaflo.co.nz/wp-content/uploads/2022/04/cropped-TF-Icon-32x32.png</url>
	<title>Homogenisation &#8211; Thermaflo</title>
	<link>https://www.thermaflo.co.nz</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Homogenisers</title>
		<link>https://www.thermaflo.co.nz/equipment/homogenisers/</link>
		
		<dc:creator><![CDATA[Ange Bocock]]></dc:creator>
		<pubDate>Tue, 09 Nov 2021 03:03:49 +0000</pubDate>
				<guid isPermaLink="false">https://thermaflowp.icepick.co.nz/?post_type=product&#038;p=6579</guid>

					<description><![CDATA[&#160;
<table class="table" style="width: 498px;">
<tbody>
<tr>
<td style="width: 134.656px;"><strong>Products</strong></td>
<td style="width: 347.344px;">All Dairy products, Juice, Edible Oils, Honey, Soups, Condiments, Plant-based dairy alternatives</td>
</tr>
<tr>
<td style="width: 134.656px;"><strong>Flow Rates </strong></td>
<td style="width: 347.344px;">50L Per Hour - 50,000L Per Hour</td>
</tr>
<tr>
<td style="width: 134.656px;"><strong>1st Stage Pressure</strong></td>
<td style="width: 347.344px;">0 - 2000 Bar</td>
</tr>
<tr>
<td style="width: 134.656px;"><strong>2nd Stage Pressure </strong></td>
<td style="width: 347.344px;">0 - 150 bar</td>
</tr>
<tr>
<td style="width: 134.656px;"><strong>Aseptic Version</strong></td>
<td style="width: 347.344px;">Available as an option</td>
</tr>
</tbody>
</table>]]></description>
										<content:encoded><![CDATA[<h2>Homogenisation is the process where the particle size in the product (measured in µm) is broken down and dispersed throughout</h2>
<p>The most common application for homogenisation in dairy is to disperse the cream in milk or ice cream mix into a homogenous emulsion, preventing future cream separation and keeping the product in a consistent state over time.</p>
<p>Homogenisation occurs via mechanical means, the product is subjected to high pressure/velocity as it is forced through a small orifice causing turbulence and cavitation thus high shear breaking the particles down and dispersing them throughout.</p>
<p>Homogenisers are also used for various different pharmaceutical or laboratory applications. With a fully integrated design and process team at Thermaflo, we are able to specify the correct homogeniser and high-pressure pump units specifically for your application.</p>
<p>&nbsp;<br />
<iframe width="624" height="351" src="https://www.youtube.com/embed/0LFeTl_c18Y" title="FBF ITALIA - Buffalo Series Homogenizer" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Positive Displacement Pumps</title>
		<link>https://www.thermaflo.co.nz/equipment/positive-displacement-pumps/</link>
		
		<dc:creator><![CDATA[Richard Ram]]></dc:creator>
		<pubDate>Tue, 31 Aug 2021 01:52:00 +0000</pubDate>
				<guid isPermaLink="false">https://thermaflowp.icepick.co.nz/?post_type=product&#038;p=5284</guid>

					<description><![CDATA[&#160;

<span dir="ltr" role="presentation"><strong>Standard flow rate:</strong> from 180 to 3000 gph</span><br role="presentation" /><span dir="ltr" role="presentation"><strong> Standard pressure range from:</strong> 600 to 3000 psi</span><br role="presentation" /><span dir="ltr" role="presentation"><strong> Standard electric motors from:</strong> 3 to 75 kW</span>

<span dir="ltr" role="presentation">CIP ready </span><br role="presentation" /><span dir="ltr" role="presentation">Suitable for treatment of low and high viscosity products.</span>

&#160;]]></description>
										<content:encoded><![CDATA[<p>Positive Displacement Pumps are used in processes where very high pressure is required e.g. evaporated milk prior to spray drying, or a high viscosity product, such as tomato paste.</p>
<p><span dir="ltr" role="presentation">The compression head is manufactured from a single block </span><span dir="ltr" role="presentation">of high quality, special type, ultrasounds checked stainless </span><span dir="ltr" role="presentation">steel, with a 5 year guarantee against cracks and defects.</span></p>
<p><span dir="ltr" role="presentation">Valve assembly housed within an individually inspectable </span><span dir="ltr" role="presentation">AISI 316 stainless steel block</span></p>
<p><span dir="ltr" role="presentation"> Pumping Pistons manufactured with a rear cooling chamber, </span><span dir="ltr" role="presentation">a double guide to keep a perfect alignment, and a special </span><span dir="ltr" role="presentation">“Diamond-Like Carbon” plating as a standard</span></p>
<p><span dir="ltr" role="presentation">Valve group assemblies have replaceable seats and </span><span dir="ltr" role="presentation">hemispherical valve shutters, ideal for processing a variety </span><span dir="ltr" role="presentation">of products</span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lab Scale Homogenisers</title>
		<link>https://www.thermaflo.co.nz/equipment/lab-scale-homogenisers/</link>
		
		<dc:creator><![CDATA[ThermafloAdmin]]></dc:creator>
		<pubDate>Tue, 03 Aug 2021 00:13:19 +0000</pubDate>
				<guid isPermaLink="false">https://thermaflowp.icepick.co.nz/?post_type=product&#038;p=854</guid>

					<description><![CDATA[<table class="table" style="width: 100%;" cellspacing="2" cellpadding="2" align="center">
<tbody>
<tr>
<td></td>
<td style="text-align: center;"><em>Lab Homogeniser 2.20</em>
<em> (1800 bar)</em></td>
<td style="text-align: center;"><em>Lab Homogeniser 2.50</em>
<em> (600 bar)</em></td>
</tr>
<tr>
<td><strong>Weight (Kg)</strong></td>
<td style="text-align: center;">110</td>
<td style="text-align: center;">110</td>
</tr>
<tr>
<td><strong>Dimensions: (LxDxH cm)</strong></td>
<td style="text-align: center;">46 x 75 x 64 (75)</td>
<td style="text-align: center;">46 x 75 x 64 (75)</td>
</tr>
<tr>
<td><strong>Electric motor</strong></td>
<td style="text-align: center;">1.5 kW, 6P., 3F.</td>
<td style="text-align: center;">1.5 kW, 6P., 3F.</td>
</tr>
<tr>
<td><strong>Capacity (L/h)</strong></td>
<td style="text-align: center;">20/24</td>
<td style="text-align: center;">50/58</td>
</tr>
<tr>
<td><strong>Max. pressure (bar)</strong>
<strong> (1°/2° stage)</strong></td>
<td style="text-align: center;">1,800/150</td>
<td style="text-align: center;">600/150</td>
</tr>
<tr>
<td><strong>Max. size of particles (mm)</strong></td>
<td style="text-align: center;">≤ 0.2</td>
<td style="text-align: center;">≤ 0.5</td>
</tr>
<tr>
<td><strong>Hopper capacity (L)</strong></td>
<td style="text-align: center;">0.8/1.6</td>
<td style="text-align: center;">0.8/1.6</td>
</tr>
</tbody>
</table>
&#160;]]></description>
										<content:encoded><![CDATA[<p><span dir="ltr" role="presentation">Our lab scale homogenisers </span><span dir="ltr" role="presentation">are designed for easy installation (no need for </span><span dir="ltr" role="presentation">water for cooling of pistons) and use (manual adjustment of homogenising pressure via handwheels).</span></p>
<p><span dir="ltr" role="presentation">Both models have a double homogenising stage and with a pressurizable hopper with a capacity of 0.8 or 1.6 litres.</span></p>
<p><span dir="ltr" role="presentation">Both models are equipped with two pumping pistons, so the lab-scale processing results are comparable/replicable with larger commercial-scale models</span><span dir="ltr" role="presentation">.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
